Contact Our Team
SARGENT/ASSA ABLOY 9200 Series High Security Locksets
Thumb

SARGENT/ASSA ABLOY 9200 Series High Security Locksets

Designed for use on openings subject to extreme abuse, vandalism, and malicious impact, the 9200 Series High Security Mortise Lockset is constructed of high quality components to maximize security and durability. It is well-suited for exposed perimeter doors in commercial facilities and its universal, non-handed curved lip strike allows for increased functionality and added versatility.

BENEFITS

 

  • Available as electromechanical locks in fail-safe or fail-secure version
  • Security screws prevent tampering of the rose
  • Certified ANSI/BHMA A156.13 Series 1000 Operational and Security Grade 1
  • Complies with ASTMF1577-95B Detention Locks for Swinging Doors
Functions
Function ANSI Name Description  Rendering
Single Cylinder without Deadbolt
04 F07 Storeroom or Closet
  • Key outside or lever/knob inside retracts latchbolt
  • Lever/Knob outside rigid at all times
  • Lever/Knob inside always retracts latchbolt
  • Auxiliary deadlatch
f-9200_high_security_locksets-04
05 F04 Office or Entry
  • Key outside retracts latchbolt when outside lever/knob is locked
  • Lever/Knob inside retracts latchbolt only, outside lever/knob remains locked
  • Lever/knob outside is locked/unlocked by thumbturn inside or by key outside
  • Auxiliary deadlatch
f-9200_high_security_locksets-05
06 Storeroom or Service
  • No outside lever/knob, cylinder only
  • Lever/knob inside or key outside retracts latchbolt
  • Auxiliary deadlatch
  • Same as 04 function without lever/knob outside
f-8200_mortise_lock-06
37 F05 Classroom
  • Key outside locks and unlocks lever/knob outside
  • Key outside retracts latchbolt
  • Lever/knob outside retracts latchbolt, except when outside lever/knob is locked by key
  • Lever/knob inside always retracts latchbolt
  • Auxiliary deadlatch
f-r8200-37
55 Office or Entry
  • Key outside retracts latchbolt when outside lever/knob is locked
  • Lever/knob inside retracts latchbolt only, outside lever/knob remains locked
  • Lever/knob outside is locked by toggle only
  • Auxiliary deadlatch
f-r8200-55
Single Cylinder with Deadbolt
24 F21 Storeroom Door
  • Key outside or thumbturn inside retracts and projects deadbolt
  • Lever/knob either side retracts latchbolt
  • Latchbolt and deadbolt are independent of each other
f-8200_mortise_lock_with_bhl_trim-24
25 F13 Dormitory or Exit
  • Key outside or thumbturn inside retracts and projects deadbolt
  • Lever/knob from either side retracts latchbolt, when the deadbolt is in the retracted position
  • Lever/knob outside is locked, when the deadbolt is projected
  • When deadbolt is projected, lever/knob inside retracts latchbolt and deadbolt simultaneously, unlocking outside lever/knob
f-8200_series_mortise_lock-25
35 Storeroom
  • Key outside retracts and projects deadbolt
  • Lever/knob outside retracts latchbolt, except when deadbolt is projected
  • Inside: no lever/knob or cylinder
 f-8200_mortise_lock-35
43 F20 Apartment Corridor Door
  • Key outside or thumbturn inside retracts and projects deadbolt
  • Key outside retracts both latchbolt and deadbolt, lever/knob outside remains locked
  • Lever/knob from either side retracts latchbolt, except when lever/knob outside is locked
  • Lever/knob outside is locked by toggle or projecting deadbolt
  • Lever/knob outside is unlocked by toggle only
  • Lever/knob inside (when deadbolt is projected) retracts latchbolt and deadbolt simultaneously, and lever/knob outside remains locked
  • Auxiliary deadlatch
f-8200_series_mortise_lock-43
45 F12 Dormitory or Exit
  • Key outside or thumbturn inside retracts and projects deadbolt
  • Key outside retracts both latchbolt and deadbolt, lever/knob outside remains locked
  • Lever/knob from either side retracts latchbolt, except when lever/knob outside is locked
  • Lever/knob outside is locked by toggle or projecting deadbolt
  • Lever/knob inside (when deadbolt is projected) retracts latchbolt and deadbolt simultaneously, and lever/knob outside remains locked
  • Same as 43 function without auxiliary deadlatch
f-8200_mortise_lock-45
50 F15 Hotel Guest
  • Hotel cylinder required (50 function cylinder) with two types of keys (standard & emergency)
  • Standard key outside retracts latchbolt only, will not retract or project deadbolt
  • Emergency key outside will retract latchbolt and deadbolt and also project deadbolt
  • Thumbturn inside retracts and projects deadbolt
  • When the deadbolt is projected, it shuts out all keys except the emergency key
  • Lever/knob inside retracts both latchbolt and deadbolt simultaneously
  • Lever/knob outside is always rigid
  • Auxiliary deadlatch
  • Not available with Mogul (M-) option
  • Not available with certain key systems (See option chart in catalog)
f-8200_mortise_lock_50
Double Cylinder without Deadbolt
16 F09 Apartment, Exit or Public Restroom
  • Key outside retracts latchbolt, when outside lever/knob is locked
  • Key inside is required to lock and unlock lever/knob outside
  • Lever/knob either side retracts latchbolt, unless outside lever/knob is locked by key inside
  • Lever/knob inside is always operable
  • Auxiliary deadlatch
  • Special cam required for inside cylinder
f-8200_mortise_lock-16
17 F30 Asylum or Institutional
  • Key from either side retracts latchbolt
  • Lever/knob on both sides rigid at all times
  • Auxiliary deadlatch
f-8200_mortise_lock-17
38 F32 Classroom Security Intruder Latchbolt
  • Key from either side locks and unlocks lever/knob outside
  • Key from either side retracts latchbolt
  • Lever/knob outside retracts latchbolt, except when outside lever/knob is locked by key
  • Lever/knob inside always retracts latchbolt
  • Auxiliary deadlatch
  • Same as 37 function with two cylinders
f-8200_mortise_lock-38
59 School Security/Double Locking
  • Key from eith side locks and unlocks inside and outside levers/knobs
  • Key from either side retracts latchbolt
  • Key from either side can retract latchbolt without unlocking levers/knobs
  • Auxiliary deadlatch
 f-8200_mortise_lock_59
Double Cylinder with Deadbolt
26 F14 Store Door
  • Key from either side retracts and projects deadbolt
  • Lever/knob from either side retracts latchbolt
  • Latchbolt and deadbolt are independent of each other
  • Same as 24 function with two cylinder and no thumbturn
f-8200_mortise_lock-26
39 F33 Classroom Security Intruder Deadbolt
  • Key either side retracts or projects deadbolt to unlock or lock lever/knob outside
  • Lever/knob outside retracts latchbolt, except when outside lever/knob is locked by key
  • Lever/knob inside retracts both latchbolt and deadbolt simultaneously, and unlocks lever/knob outside
  • Same as 25 functions with a cylinder inside a place of a thumb turn
f-8200_mortise_lock-39
40  F34 Classroom Security Intruder Deadbolt
  • Key either side retracts or projects deadbolt to unlock or lock lever/knob outside
  • Lever/knob outside retracts latchbolt, except when outside lever/knob is locked by key
  • Lever/knob inside retracts both latchbolt and deadbolt simultaneously, and unlocks lever/knob outside
  • Auxiliary deadlatch
  • Same as 39 function with Auxiliary deadlatch
 f-8200_mortise_lock-40
41 Classroom Security/Intruder Deadbolt
  • Key from either side retracts and projects deadbolt
  • Key retraction of deadbolt, lever/knob outside remains locked
  • Key retraction of latchbolt from either side unlocks lever/knob outside
  • Lever/knob outside retracts latchbolt, except when outside lever/knob is locked by key
  • Lever/knob outside is locked when the deadbolt is projected
  • Lever/knob inside (when deadbolt is projected) retracts both latchbolt and deadbolt simultaneously, and lever/knob outside remains locked
  • Auxiliary deadlatch
 f-8200_mortise_lock_41
49 Security Deadbolt
  • Key from either side retracts and projects deadbolt
  • Key from either side retracts latchbolt
  • Levers/knobs inside & outside are locked only when deadbolt is projected
 f-8200_mortise_lock_49
Non-Keyed
15 F01 Passage or Closet
  •  Lever/knob from either side retracts latchbolt at all times
f-8200_mortise_lock_15
65 F22 Privacy Bedroom or Bath
  •  Lever/knob outside retracts latchbolt except when locked by thumbturn inside
  • Lever/knob inside retracts latchbolt and unlocks outside lever/knob
  • Emergency release unlocks lever/knob outside
  • Thumbturn locks and unlocks lever/knob outside
  • Closing the door will unlock lever/knob outside
f-8200_mortise_lock_65
66  F19 Privacy Bedroom or Bath
  • Lever/knob outside retracts latchbolt except when deadbolt is projected
  • Lever/knob inside retracts both latchbolt and deadbolt simultaneously, and unlocks outside lever/knob
  • Emergency release retracts and projects deadbolt
  • Thumbturn retracts and projects deadbolt
f-8200_mortise_lock_66
Deadbolt Only
03 Classroom Deadlock
  • Deadbolt operation only
  • Key outside retracts and projects deadbolt
  • Key outside retracts and projects deadbolt
  • Thumbturn inside retracts deadbolt only, will not project it
 f-8200_mortise_23
20 F18 Deadlock
  • Deadbolt operation only
  • Key outside retracts and projects deadbolt
  • No inside operation
f-8200_mortise_lock-20
21 F17 Deadlock
  • Deadbolt operation only
  • Key outside retracts and projects deadbolt
  • Thumbturn inside retracts and projects deadbolt
f-8200_mortise_lock-21
22 F16 Deadlock
  • Deadbolt operation only
  • Keyoutside or inside retracts and projects deadbolt
f-8200_mortise_lock_22
23 Classroom Deadlock
  • Deadbolt only operation
  • Key outside or inside retracts and projects deadbolt
  • Thumburn inside retracts deadbolt, does not project deadbolt
  • Same as 03 function with an extra cylinder inside
 f-8200_mortise_lock-23
Electromechanical Functions
70 Electromechanical Fail Safe
  •  Power ON, locks outside lever (by solenoid)
  • Always specify voltage: 12VDC or 24VDC
  • Key outside retracts latchbolt, when the lever outside is locked
  • Lever outside retracts latchbolt except when lever outside is locked
  • Lever outside can only be locked with the solenoid
  • Lever inside always retracts latchbolt
  • Supplied with Electrolynx connectors
  • Auxiliary deadlatch
 f-8200_mortise_lock_70
71 Electromechanical Fail Secure
  •  Power OFF, locks outside lever (by solenoid)
  • Always specify voltage: 12VDC or 24VDC
  • Key outside retracts latchbolt, when the lever outside is locked
  • Lever outside retracts latchbolt except when lever outside is locked
  • Lever outside can only be locked with the solenoid
  • Lever inside always retracts latchbolt
  • Supplied with Electrolynx connectors
  • Auxiliary deadlatch
 f-8200_mortise_lock-71
72 Electromechanical Fail Safe
  •  Power ON, locks both levers (by solenoid)
  • Solenoid activated mortise lock
  • Always specify voltage: 12VDC or 24VDC
  • Key on either side retracts latchbolt, when the levers are locked
  • Lever from either side retracts latchbolt, except when lever is locked
  • Lever on both sides can be locked with the solenoid
  • Lever cannot be locked separately, only together
  • Supplied with Electrolynx connectors
  • Auxiliary deadlatch
 f-8200_mortise_lock-72
73 Electromechanical Fail Secure
  •  Power OFF, locks both levers (by solenoid)
  • Solenoid activated mortise lock
  • Always specify voltage: 12VDC or 24VDC
  • Key on either side retracts latchbolt, when the levers are locked
  • Lever from either side retracts latchbolt, except when lever is locked
  • Lever on both sides can be locked with the solenoid
  • Lever cannot be locked separately, only together
  • Supplied with Electrolynx connectors
  • Auxiliary deadlatch

SARGENT/ASSA ABLOY 9200 Series High Security Locksets