Specifications
Operators for interior doors shall be products of one manufacturer and be matched in style. Operator (non-fire rated doors) closing force shall be adjustable to ensure adequate closing control and shall simulate conventional door closer opening and closing forces unless the power operator motor is activated or in the event of a power outage to the operator. Operators shall be non-handed and have electrically controlled backcheck, sweep, and latch with manual adjustment to set both the full open and full closed door positions. Maximum door open shall be adjustable up to 95°, pull side mounting, conditions permitting. Operators can be SELECTIVELY ACTIVATED (i.e. external wall switches, radio frequency devices). Operators shall have input line rating of 120VAC, .6A, and include on board relay contact for interfacing with products having a rating of 24VDC at 1A. Door operators shall include an external On/Off Switch to defeat powered opening cycle and an internal circuit breaker switch to interrupt input power for servicing. Operators shall be ETL certified and conform to ANSI/U.L. standard 325 for automatic closing doors. Door operators shall be in compliance with the requirements of the Americans with Disabilities Act (ADA) and ANSI/BHMA standard A117.1.
Additional Detailed Specifications
When activated, the door operator shall, by means of an integral motor, power open the door at both a speed and force adjustable to meet accessibility codes. The door shall be powered from a door closed position to a full door open position and remain in momentary hold open for 0 to 30 seconds (adjustable 0 to 30 seconds); (A.D.A requires 5 seconds minimum hold open). Operators shall be capable of allowing the door to be opened manually from 0 to 95°, conditions permitting. Once door operator reaches full hold open position, if reinitiated, the momentary hold open time shall restart from the initially set hold open time. If door operator is initiated during the closing cycle, the operator shall revert to opening cycle beginning at that door position. Obstruction detection during opening shall neutralize and reverse motor action reverting motor to closed position allowing door to close by means of the integral motor. The obstruction detection feature shall be integral to the door operator. During closing cycle, the door operator shall close door by means of integral motor power not to exceed a closing force of 15 lbf. In the event of power loss, the door will remain in the position at the time of the power loss during the opening or the closing cycles. -
Finishes
689 Aluminum
690 Statuary Bronze
-
Features
- Push or pull side mounting
- Non-handed
- Quiet operation
- Electrically controlled backcheck, sweep and latch
- Activation options: wall switches, radio frequency devices
- Ease of installation and set-up
- On/Off Switch
- Hold open options: 0-30 seconds (5 seconds minimum required for ADA and ANSI/BHMA A156.19)
- Onboard 24VDC (1.1A) power supply for accessories
- Door closer mode for manual usage
- Electronic motor dampening – provides feel of normal, manual door closer
- Electric hardware and access control interface
- Optional AC power cord
-
Benefits
- Affordable functionality: simply opens and closes the door to automate interior, non-fire rated doors
- Ideal for retrofit applications: easy installation and optional AC power cord effortlessly converts openings for barrier free accessibility
- Consistent and dependable: quiet electromechanical operation meets ADA requirements and provides easy access
- Hands-free operation: ideal for public restrooms or upgrading openings for ADA compliance when used with touchless wall switches
-
Typical Applications
- Touchless applications
– Public restrooms
– Laboratories
– Examination rooms
- Retrofit applications to meet ADA
– Offices
– Classrooms
– Dorm rooms
- Touchless applications
-
Electrical Data
- Relay Output: SPDT
– Normally Open/Normally Closed (jumper)
– For electric strike function
- Power Input; 120 VAC, 60Hz
- Current Draw: .6A
- Auxiliary Output: 24VDC @ 1.1A
- Relay Output: SPDT
Videos
-
How to Use Video Intercom Easy UI 2.0 on Hikvision Indoor Monitor
How to setup Hikvision Modular Intercom with single Indoor Monitor
How to add additional Indoor extensions to Hikvision Modular Intercom
How to add additional Sub Door Station to Hikvision Modular Intercom
How to configure calling schedules on Hikvision Intercoms
How to set passwords on Hikvision's Modular intercoms
-
How to Use Video Intercom Easy UI 2.0 on Hikvision Indoor Monitor
How to setup Hikvision Modular Intercom with single Indoor Monitor
How to add additional Indoor extensions to Hikvision Modular Intercom
How to add additional Sub Door Station to Hikvision Modular Intercom
How to configure calling schedules on Hikvision Intercoms
How to set passwords on Hikvision's Modular intercoms