HANGER HS4 AElement Fusion Mortise

Grade 1
HS4 AElement
Applications: – Where customizable designer handle sets are desired
– Interior openings
Specs
Lock Types:  – To be used only with Salto AElement mortise locks
– Without privacy, no deadbolt
– Privacy, deadbolt
Programmable Lock Modes: – Programs can be customized by user and by opening
– Standard – locked at all times
– Office Mode – free passage (can be set to revert to standard)
– Timed Office – automatic locking at end time
– Automatic Opening – 8 pairs of “hands-free” timed lock and unlocks
per day with holidays
– Toggle – present card to lock, present card to unlock
– Timed Toggle – present card to lock, present card to unlock depending on schedule
– Exit Leaves Open Mode – lock remains unlocked after the inside handle is used
Technological Specifications:
Platforms: – SVN
– BLUEnet (including SVN+Flex)
ID Technologies: – Mifare (DESfire EV1, Plus, Ultralight C, Classic – ISO/IEC14443)
– Bluetooth SMART (BLE)
– NFC
Smartphone Capability: – Android (2.3.3 version minimum)
– IOS
System Security: – Secure Socket Layer (SSL)
– AES 128 Bit encryption opening procedures
Management Software: – Salto ProAccess SPACE
Network Configuration: – Offline Only (default) – can only be used as a SVN lock.
Power Source: – (3) alkaline AA 1.5V batteries  up to 50,000 transactions
Operating Temperature: –  0º F to 140º F (not suitable for exterior openings)
Mechanical Specifications
Door Thickness: – From 1-3/8″ – 1-3/4″ up to 4-1/2″ – 4 15/16″
Mortise Lock Dimensions: – 6.1″ (H) x 6.4″ (W)
Mortise Lock Backset – 2-3/4″
Reader Dimensions: – 1.8″ (H) x  1.8″ (W) x 0.3″ (D)
Lever Styles:  – All AElement must be ordered handed
– Archer, Joshua, Withnell, William  (see lever options under Related Files)
– Additional styles offered
Standard Lever Finishes: – US3, US4, US32, US32D, BLK
Mortise Lock Finishes: – US3, US32D
Reader Cover Finishes: – White, black
Warranty:  – One year
Certifications:  – Declaration of Conformity CE
Use of Radio Frequency Spectrum: – ETSI EN 328 V1.7.1 (2006-10); ETSI EN 300 330-1 V1.3.1 (2006-10); EST EN 300 330-1 V1.3.1 (2006-04)
Electromagnetic Compatibility: – ETSI EN 301 489-1 (2011-09); ETSI EN 301 489-3 (2002-08)
Security Requirements: – EN 60950-1 (2007)
Mechanical:  – UL10C – 45 minutes
– BHMA Certified ANSI A156.13, Series 1000, Grade 1, Operational and Security
– UL/cUL Listed for all functions up to 3 hours for “A” label single doors
– UL 10C Positive Pressure Rated