Capabilities:
- Easily manages up to 3,000 Users per lock
- Manages up to 16 access schedules per lock; unlimited schedules in the software database
- Manages up to 32 holidays/vacations blocks per lock; unlimited holidays/vacations in the software database
- Guest/visitor management with programmable expiry using DESFire read/write cards
- Service users can be programmed for one shot or “come-and-go” access for 1 to 96 hours—using DESFire cards
- Lock settings and related parameters are easily cloned, permitting quick multi-lock installations
- Access group management to quickly assign a very large number of users to a door or vise versa
- Temporary user card management for lost card situations using DESFire cards
- Manual and Automatic Passage modes
Data Protection:Â Passwords unique site key and SQL database ensure integrity of system and data
Access Granting Credentials:
- Card only (FIPS-201 compliant or DESFire card)
- Dual credential—PIN followed by card
Personal ID Verification Interface:
- Contactless Interface ISO 14443A/B
- ID Card Enrolling Station: Read/Write Enroller that supports both (ISO7816-4) Contact Interface and (ISO 1443A) Contactless Interface
ID Card Enrolling Station:Â Read/Write Enroller that supports both (ISO 7816-4) Contact Interface and (ISO 1443A) Contactless Interface
Lock Programming & Auditing Unit:Â Any Windows XP Home OS or up-based Network or Laptop PC with dormakaba-supplied IrDA Interface Kit (included with FIPS 201 software)
Number of Users:Â 3,000 Users
Audit Events in Lock:Â 30,000 Events
- Reports
Audit:Â Lock records last 30,000 Events to provide increased accountability; audit also records mechanical key override use
- Report Options:Â User Report by Doors, Door Report By Users, System Operator Report, Audit of PC Activity, Access Schedules Report, Holiday/Vacations Report, Access Groups Reports, etc.
Authority Levels
- Master: One global Master per entire system; 24/7 access to all locks with no schedule or lockout restrictions; can also program and audit locks
- Manager: Schedule-based access—with no expiry; can also program and audit lock
- Access User: Schedule-based access; can only access lock—with no expiry
- Guest/Visitor: Schedule-based access; can only access lock—with maximum 1 year expiry
- Service: 24/7 PIN only access—one-time access, or 1 through 96 hour expiry access, or no expiry access
- M-Unit (Data Transfer): 24/7 data transfer capability (programming and/or auditing) of lock on site only; no entry access to any lock on site allowed
Operation Modes
- Manual Passage: Toggle passage mode on/off at lock keypad by the Master or the Manager(s)
- Scheduled Access: Access granted per schedules and access privileges
- First “Privileged User” In Passage: Lock enters passage mode after a “privileged” User or Manager opens lock at, or after the start of scheduled access start time
- Auto Passage: Lock enters passage mode automatically at the start of scheduled access start time
- Lockout: Only the Master or the emergency mechanical key can override the lockout