Dahua PFM920I-6U-C

UTP CAT6 Cable

> 305 m (1000 ft)/carton UTP CAT6, power over Ethernet, compatible   with one cable > High-purity oxygen-free copper conductor material > Customized PVC outer sheath; CE CPR Eca flame retardant class  certified > 10-year warranty
Specifications
  • Conductor
    Material Oxygen free copper (99.97% purity)
    Diameter 0.57 mm ± 0.01 mm
    American Wire Gauge 23AWG
    Insulation
    Material HDPE
    Min. Average Thickness 0.21 mm
    Diameter 1.0mm±0.1mm
    Color (4 Pairs) Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown
    Separator
    Material PE
    Specification Translucent 4.5 × 0.4 mm
    Rip Cord
    Material Polyester
    Specification 500D
    Sheath
    Material PVC
    Min. Average Thickness 0.5 mm
    Diameter 6.3 mm ± 0.3 mm
    Color White
    Electrical
    Max. DC Resistance of a Single Conductor 7.5Ω/100 m
    Min. Insulation Resistance 5000MΩ·km
    Max. DC Resistance Unbalance 2% (pair intra), 4% (pairs inter)
    Dielectric Strength No breakdown with 1KV DC for 1 min
    Transmission
    Characteristic Impedance 100 ± 15Ω
    Near End Cross Talk ≥39.30 dB/100 m@250 MHz
    Max. Attenuation 33 dB/100 m@250 MHz
    Return Loss ≥17.3 dB/100 m@250 MHz
    Mechanical
    Tensile Strength Sheath≥9 MPa, insulation≥16 MPa
    Elongation at Break Sheath≥100%, insulation≥100%
    Installation Bending Radius >8 times of outer cable diameter
    Conductor Elongation at Break ≥8%
    Environmental
    Shrinkage of Insulation ≤5%
    Color Migration Resistance of Insulation No migration
    Sheath Tensile Strength and Elongation at Break after Aging ≥6.3 MPa, ≥100%
    Low Temperature Bending Test No cracking after the test
    Heat Shock Test No cracking after the test
    Operating Temperature –20°C to +60°C (–4°F to 140°F)
    Installation Temperature 0°C to +50°C (32°F to 122°F)
    Storage Temperature and Humidity –10°C to +40°C (14°F to 104°F), <60% (RH)
    Security
    Vertical Fire Propagation Test Comply with IEC 60332-1-2
    Packaging
    Cable Length 305.0 m (1000.66 ft) ± 1.5 m (4.92 ft)
    Inner Carton Dimensions 416.0 mm × 412.0 mm × 220.0 mm (16.38" × 16.22" × 8.66") (L × W × H)
    Packaging Method 305.0 m (1000.66 ft) a carton, one master carton with 2 inner cartons
    Net Weight ≥11.9 kg (26.24 lb)
    Gross Weight ≥12.9 kg (28.44 lb)
    Compliance
    Executive Standards ISO/IEC 11801-1-2017, IEC 61156-5-2009
    Certification
    Certification CPR Eca
    Transmission Characteristics
    (100 m at 20°C) (328.08 ft at 68°F)
    Frequency (MHz) Phase delay ≤ ns IL ≤ dB TCL≥ dB﹡ EL TCTL≥ dB﹡ NEXT ≥ dB PS NEXT ≥ dB
    1 n/s n/s 50.0 35.0 n/s n/s
    4 552.0 3.8 44.0 23.0 66.3 63.3
    8 547.0 5.4 41.0 16.9 61.8 58.8
    10 545.0 6.0 40.0 15.0 60.3 57.3
    16 543.0 7.6 38.0 10.9 57.2 54.2
    20 542.0 8.5 37.0 9.0 55.8 52.8
    25 541.0 9.6 36.0 7.0 54.3 51.3
    30﹡ 540.6 10.5 35.2 5.5 53.1 50.1
    31.25 540.0 10.7 35.1 n/s 52.9 49.9
    62.5 539.0 15.5 32.0 n/s 48.4 45.4
    100 538.0 19.9 30.0 n/s 45.3 42.3
    200 537.0 29.1 27.0 n/s 40.8 37.8
    250 536.0 33.0 26.0 n/s 39.3 36.3
    Frequency (MHz) EL FEXT ≥ dB PS EL FEXT ≥ dB RL ≥ dB Delay skew ≤ ns Zc(Ω)
    1 n/s n/s n/s n/s n/s
    4 56.0 53.0 23.0 45.0 100±15
    8 49.9 46.9 24.5
    10 48.0 45.0 25.0
    16 43.9 40.9 25.0
    20 42.0 39.0 25.0
    25 40.0 37.0 24.3
    30﹡ 38.5 35.5 23.8
    31.25 38.1 35.1 23.6
    62.5 32.1 29.1 21.5
    100 28.0 25.0 20.1
    200 22.0 19.0 18.0
    250 20.0 17.0 17.3
    Note:  Executive standard for the above parameters: ISO/IEC 11801-1-2017"n/s"=Not Specified "﹡"=Unless otherwise customer stated the test results default to not shown in test report but comply with standard