Contact Our Team

Dahua PFM920I-5EU-U

UTP CAT5e Cable

> 305 m (1000 ft)/carton UTP CAT5e, power over Ethernet, compatible with one cable

> High-purity oxygen-free copper conductor material

> Customized PVC outer sheath; ANSI UL CM flame retardant class   certified

> 10-year warranty

Specifications
  • Conductor
    Material Oxygen free copper (99.97% purity)
    Diameter 0.50 mm ± 0.01 mm
    American Wire Gauge 24AWG
    Insulation
    Material HDPE
    Min. Average Thickness 0.18 mm
    Diameter 0.90mm±0.1mm
    Color (4 Pairs) Blue, white/blue; orange, white/orange; green, white/green; brown, white/brown
    Rip Cord
    Material Polyester
    Specification 500D
    Sheath
    Material PVC
    Min. Average Thickness 0.5 mm
    Diameter 5.1 mm ± 0.3 mm
    Color White
    Electrical
    Max. DC Resistance of a Single Conductor 9.38Ω/100 m
    Min. Insulation Resistance 5000MΩ·km
    Max. DC Resistance Unbalance 5% (pair intra)
    Dielectric Strength No breakdown with 2.5KV DC for 2 seconds
    Transmission
    Characteristic Impedance 100 ± 15Ω
    Near End Cross Talk ≥35.30 dB/100 m@100 MHz
    Max. Attenuation 22.0 dB/100 m@100 MHz
    Return Loss ≥20.1 dB/100 m@100 MHz
    Mechanical
    Tensile Strength Sheath≥13.8 MPa, insulation≥16.5 MPa
    Elongation at Break Sheath≥100%, insulation≥300%
    Installation Bending Radius >8 times of outer cable diameter
    Conductor Elongation at Break ≥10%
    Environmental
    Shrinkage of Insulation ≤6%
    Color Migration Resistance of Insulation No migration
    Sheath Tensile Strength and Elongation at Break after Aging ≥11.73 MPa, ≥50%
    Low Temperature Bending Test No cracking after the test
    Heat Shock Test No cracking after the test
    Operating Temperature –20°C to +60°C (–4°F to 140°F)
    Installation Temperature 0°C to +50°C (32°F to 122°F)
    Storage Temperature and Humidity –10°C to +40°C (14°F to 104°F), <60% (RH)
    Security
    Vertical Fire Propagation Test Comply with UL1685(without smoke measurements)
    Packaging
    Cable Length 305.0 m (1000.66 ft) ± 1.5 m (4.92 ft)
    Inner Carton Dimensions 364.0 mm × 364.0 mm × 216.0 mm (14.33″ × 14.33″ × 8.50″) (L × W × H)
    Packaging Method 305.0 m (1000.66 ft) a carton, one master carton with 2 inner cartons
    Net Weight ≥8.0 kg (17.64 lb)
    Gross Weight ≥9.0 kg (19.84 lb)
    Compliance
    Executive Standards ANSI/TIA 568-C.2-2009, UL444-2008
    Certification
    Certification UL CM
    Transmission Characteristics

    (100 m at 20°C) (328.08 ft at 68°F)

    Frequency (MHz) Phase delay ≤ ns IL ≤ dB NEXT ≥ dB PS NEXT ≥ dB ACRF ≥ dB
    1 570 2.0 65.3 62.3 63.8
    4 552 4.1 56.3 53.3 51.8
    8 547 5.8 51.8 48.8 45.7
    10 545 6.5 50.3 47.3 43.8
    16 543 8.2 47.2 44.2 39.7
    20 542 9.3 45.8 42.8 37.8
    25 541 10.4 44.3 41.3 35.8
    31.25 540 11.7 42.9 39.9 33.9
    62.5 539 17.0 38.4 35.4 27.9
    100 538 22.0 35.3 32.3 23.8
    Frequency (MHz) PS ACRF ≥ dB RL ≥ dB Delay skew ≤ ns Zc(Ω)
    1 60.8 20.0 n/s n/s
    4 48.8 23.0 45.0 100±15
    8 42.7 24.5
    10 40.8 25.0
    16 36.7 25.0
    20 34.8 25.0
    25 32.8 24.3
    31.25 30.9 23.6
    62.5 24.9 21.5
    100 20.8 20.1
    Note: 

    Executive standard for the above parameters: ANSI/TIA-568-C.2-2009

Get Pricing