BEA’s IXIO-ST INDUSTRIAL is an effective, versatile and easy-to-use presence sensor for interior industrial doors, automatic sliding doors and off-door industrial automation. It can be used for both clear door openings and side-lite protection.
Precise infrared curtains coupled with visible alignment beams make the IXIO-ST INDUSTRIAL extremely safe and easy to adjust. This state-of-the-art sensor features an on-board LCD screen that streamlines the installation and setup processes.
The IXIO-ST INDUSTRIAL has earned a comprehensive list of credentials and certifications, including FCC and IP54.
Two 24-spot, high-density, infrared safety curtains providing precise presence detection
Four visible red alignment spots are projected on the ground to assist in precise IR curtain adjustment
Intelligent programming and troubleshooting via a menu-driven LCD
On board microprocessor optimizes data analysis, monitors sensor performance and enables system integration
TABLE OF SPECIFICATIONS
Technology | Active Infrared | |
---|---|---|
Detection Mode | Presence | |
Spot Size | 2” × 2” | |
Max. Number of Spots | 24 per curtain | |
Max. Number of Curtains | 2 | |
Output
Max. Contact Voltage |
Solid-state-relay (potential and polarity free)42 VAC / VDC 400 mA Infrared: 0.3 – 1 s |
Solid-state-relay (potential and polarity free)42 VAC / VDC 400 mA Infrared: 0.3 – 1 s |
Test Input | Low: < 1 V; High: > 10 V (max. 30 V) Response time on test request: typical: < 5 ms |
Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V) Response time on test request: typical: < 5 ms |
Supply Voltage | 12 – 24 VAC ±10%; 12 – 30 VDC ±10% (to be operated from SELV compatible power supplies only) |
|
Power Consumption | < 2.5 W | |
Mounting Height | 6 ½ – 11 ½’ | |
Temperature Range* | -13 – 131 °F 0 – 95% relative humidity, non condensing |
|
Degree of Protection | IP54 | |
Applicable Directives | R&TTE 1999 / 5 / EC; LVD 2006 / 95 / EC; MD 2006 / 42 / EC; ROHS 2 2011 / 65 / EU |
|
Dimensions | 10 3⁄5“ (W) × 2 ¼” (H) × 2 ¼” (D) | |
Cable Length | 30’ | |
Norm Conformity | ISO 13849-1:2008 PL «c» CAT. 2 (under the condition that the door control system monitors the sensor at least once per door cycle) IEC 61496-1:2012 ESPE Type 2 |
*LCD screen is operational from 14 – 131 °F. The sensor may still be programmed in colder
temperatures, but with the remote control.