BEA’s dual technology IXIO-DT1 INDUSTRIAL is a highly flexible and user friendly motion and presence sensor for interior industrial doors, vehicle gate detection and off-door automation.
This cutting-edge sensor has earned an impressive list of credentials and certifications, including FCC and IP54.
Features
Ten microwave activation sensitivity settings and three infrared safety immunity settings
Two 24-spot, high-density, infrared safety curtains providing precise presence detection
Fully monitored internally, capable of external monitoring
Four visible red alignment spots are projected on the ground to assist in precise IR curtain adjustment
TABLE OF SPECIFICATIONS
Technology | Microwave Doppler Radar | Active Infrared |
---|---|---|
Detection Mode | Motion | Presence |
Transmitter Frequency | 24.150 GHz | N/A |
Transmitter Radiated Power | < 20 dBm EIRP | N/A |
Transmitter Power Density | < 5 mW / cm2 | N/A |
Spot Size | N/A | 2” × 2” |
Max. Number of Spots | N/A | 24 per curtain |
Max. Number of Curtains | N/A | 2 |
Output
Max. Contact Voltage |
Electro-mechanical-relay (potential and polarity free) 30 VDC |
Solid-state-relay (potential and polarity free) 42 VAC / VDC |
Test Input Sensitivity |
Low: < 1 V; High: > 10 V (max. 30 V) Response time on test request: typical: < 5 ms |
Sensitivity: Low: < 1 V; High: > 10 V (max. 30 V) Response time on test request: typical: < 5 ms |
Supply Voltage | 12 – 24 VAC ±10%; 12 – 30 VDC ±10% (to be operated from SELV compatible power supplies only) |
|
Power Consumption | < 2.5 W | |
Mounting Height | 6 ½ – 11 ½’ | |
Temperature Range* | -13 – 131 °F 0 – 95% relative humidity, non condensing |
|
Degree of Protection | IP54 | |
Applicable Directives | R&TTE 1999 / 5 / EC; LVD 2006 / 95 / EC; MD 2006 / 42 / EC; ROHS 2 2011 / 65 / EU |
|
Dimensions | 10 3⁄5“ (W) × 2 ¼” (H) × 2 ¼” (D) | |
Cable Length | 30’ | |
Norm Conformity | ISO 13849-1:2008 PL «c» CAT. 2 (under the condition that the door control system monitors the sensor at least once per door cycle) IEC 61496-1:2012 ESPE Type 2 |
*LCD screen is operational from 14 – 131 °F. The sensor may still be programmed in colder
temperatures, but with the remote control.