Allegion/Schlage Scan II™ Motion Sensors

Schlage passive infrared motion sensors for request-to-exit applications are wall or ceiling mounted and designed for a adjustability of coverage area regardless of installation height.

The Scan II™ is a compact, passive infrared detector specifically designed for “request-to-exit” applications. It features adjustable relay latch time, an externally visible activation LED, and two form “C” relays.

The high-impact ABS plastic enclosure in black or white comes apart in 3 pieces for easy mounting and lock-in-place scanner angle adjustment. Internal angle setting marks aide optimal coverage configuration for both wall and ceiling mounting. Mounting height is 7 to 15 feet allowing coverage area of the Scan II sensor of up to 8 by 10 feet (2.4 m by 3 m).

Features & Benefits
Security
  • Adjustable relay latch time from 0.5 to 64 seconds
  • Field-selectable fail safe/fail secure
  • Included pattern masking kit snaps in place to narrow scan field and help prevent unwanted activations
  • Activation LED is visible at a distance and can be configured to OFF as needed
Application
  • Intended for indoor use only
  • Wall or ceiling mounted with lock-in-place angle adjustment
  • UL294 and ULC-S319, Class 1 listed by manufacturer
Design
  • High-impact ABS plastic enclosure and internal electronics can endure temperatures of -20° to 120°F
  • Inconspicuous unit is only 1.5″ x 6.25″ x 1.5″ in either black or white
Specifications
Models
  • Scan II-B: black with externally visible activation LED
  • Scan II-W: white with externally visible activation LED
Power requirements
  • 12/24 VDC: 35 mA @ 12 VDC; 38 mA @ 24 VDC when activated
  • 12/24 VAC: 42 mA @ 12 VAC; 48 mA @ 24 VAC when activated
  • 38 mAh required for standby operation (no internal standby battery)
Relay
  • Two form “C” relay contacts rated 2.0 Amp @ 30 VDC or VAC maximum for DC resistive loads
Installation options
  • Adjustable relay latch time from 0.5 to 64 seconds
  • Relay mode can be programmed to reset when timer expires or remain activated until motion stops
  • Field-selectable fail safe/fail secure
  • Mounting height of 7 to 15 feet (indoors only)
  • Lock-in-place pattern adjustment is +/- 14° with separate settings for wall vs. ceiling application