BEA IXIO-ST Industrial Presence Sensor For Small Interior Industrial Doors

Description

BEA’s IXIO-ST INDUSTRIAL is an effective, versatile and easy-to-use presence sensor for interior industrial doors, automatic sliding doors and off-door industrial automation. It can be used for both clear door openings and side-lite protection.

Precise infrared curtains coupled with visible alignment beams make the IXIO-ST INDUSTRIAL extremely safe and easy to adjust. This state-of-the-art sensor features an on-board LCD screen that streamlines the installation and setup processes.

The IXIO-ST INDUSTRIAL has earned a comprehensive list of credentials and certifications, including FCC and IP54.

Features
Precise presence detection

Two 24-spot, high-density, infrared safety curtains providing precise presence detection

Easily adjustable

Four visible red alignment spots are projected on the ground to assist in precise IR curtain adjustment

Ease of setup

Intelligent programming and troubleshooting via a menu-driven LCD

Intelligent solution

On board microprocessor optimizes data analysis, monitors sensor performance and enables system integration

TABLE OF SPECIFICATIONS

Technology Active Infrared
Detection Mode Presence
Spot Size 2” × 2”
Max. Number of Spots 24 per curtain
Max. Number of Curtains 2
Output 

Max. Contact Voltage
Max. Contact Current
Hold Time

Solid-state-relay
(potential and polarity free)42 VAC / VDC
400 mA
Infrared: 0.3 – 1 s
Solid-state-relay
(potential and polarity free)42 VAC / VDC
400 mA
Infrared: 0.3 – 1 s
Test Input Low: < 1 V;
High: > 10 V (max. 30 V)
Response time on test
request:
typical: < 5 ms
Sensitivity:
Low: < 1 V;
High: > 10 V (max. 30 V)
Response time on test
request:
typical: < 5 ms
Supply Voltage 12 – 24 VAC ±10%; 12 – 30 VDC ±10%
(to be operated from SELV compatible power
supplies only)
Power Consumption < 2.5 W
Mounting Height 6 ½ – 11 ½’
Temperature Range* -13 – 131 °F
0 – 95% relative humidity, non condensing
Degree of Protection IP54
Applicable Directives R&TTE 1999 / 5 / EC; LVD 2006 / 95 / EC;
MD 2006 / 42 / EC; ROHS 2 2011 / 65 / EU
Dimensions 10 35“ (W) × 2 ¼” (H) × 2 ¼” (D)
Cable Length 30’
Norm Conformity ISO 13849-1:2008 PL «c» CAT. 2
(under the condition that the door control system
monitors the sensor at least once per door cycle)
IEC 61496-1:2012 ESPE Type 2

*LCD screen is operational from 14 – 131 °F. The sensor may still be programmed in colder
temperatures, but with the remote control.

 